2d-Master-Folierung-Seite1 (1)

The charging power of the MASTER 480 can be adapted as required by means of expandable modules in 40 kW steps. Due to the input power of max. 546 kVA, a charging power of 3 x 22 kW (AC charging) or 3 x 160 KW (DC charging) can be guaranteed.

kv-kontur-06
CHARGING WITH DC OR AC

Various charging options

web-smart-quer-infografik-01
web-smart-infografik
MASTER 480

Technical specifications

Product Information

Charging type AC + DC
Charging standard Type 2 (AC) + CCS2 (DC)
AC rated input current and power 788 A, 546 kVA at 3 x DC (160 kW) and 3 x AC (22 kW)
Input voltage range 3 x 400 V AC (+/- 10 %)
DC output power max. 160 kW per charging point, max. 3 charging points simultaneously
AC output power (optional) max. 22 kW per charging point, max. 3 charging points simultaneously
DC output voltage 300 - 1000 V
Number of EVs served (Electrical Vehicle) max. 6
Power connection AC input 3P + PEN
Mobile communication GSM / 2G / 3G / 4G
Connectivity Internet access via 4G / 3G / Ethernet (RJ45)
Communication protocols MQTT, Profinet, OCPP
Accessories Internal load management system
Software upgrade Over-The-Air (OTA)
Earthing system TN-C
Number of charging points in the network 3 x AC / 3 x DC charging points per Power Unit, max. 10 Power Units can be interconnected

Performance Parameters

Power factor (full load) 0,98 (Load > 50 %)
THDi <= 5 % (Load > 50 %)
Efficiency 95,9 % (full load)
Power consumption in standby < 10 W per 20 kW
Max. short-circuit current 3 kA
Inrush current Negligible, < 10 % of rated current
Performance upgrade 40 kW modules can be installed

General Features

IP- and IK-classification IP54
Enclosure type (material) Powder-coated steel and aluminium housing
Operating temperature range min. -20 °C to max. +45 °C
Efficiency 95 % at full load
Ambient temperature range  min. -20 °C to max. +60 °C
Humidity 5 % to 90 %
Mounting Free-standing housing
Environment Indoor and outdoor installation
Dimensions (H x W x D) 2,10 m x 0,95 m x 0,95 m 
Weight ~ 750 kg
SIM card slot quantity 2 slots
Load management within the loading park

Certification and Standards

Charging system IEC 61851-1 Ed. 3, IEC 61851-21-2 Ed. 1, IEC 61851-23 Ed. 1, IEC 61851-24
Communication with the EV DIN SPEC 70121:2014
DOWNLOAD NOW
In our data sheet, you will find all technical specifications of the MASTER 480 power unit. Download now as pdf file.
OVERALL SYSTEM

The system principle

The CHARGE-V's MASTER 480 is a modular power unit with up to 480 kW of power available. This means that up to three charging stations can be supplied simultaneously with 160 kW each.   

Ladesystem deutsch

scalability

Scalable satellite configuration

input power

Max. Input power of 546 kVA

 

load management

Load management

Ladeleistung

Max. charging power 12 x 40 kW (DC charging) 

 

Power supply

Power supply for three charging stations simultaneously

icon-label-05White-Label
possibility

icon-schloss-04

Vandalism-proof, weatherproof

icon-anschluss

Ready for connection pre-installed

undefined-Jul-07-2021-01-25-27-87-PM

Powder-coated steel and aluminium housing

icon-kabelPower supply of up to 160 kW per charging station

Tools Silhouette
Demand-oriented module adjustment (40 kW-steps)

undefined-Jul-09-2021-09-43-39-61-AM

CE Declaration of Conformity
IEC 61851-1, IEC 61851-21, IEC 61851-23, IEC 61851-24